Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-35742240

RESUMO

In this study, effects of smoking on colour vision with the Farnsworth−Munsell 100 Hue test (FM100h) and achromatic (A), red-green (RG), and blue-yellow (BY) contrast sensitivity functions were evaluated. In total, 50 non-smoker controls and 25 smokers, divided into two groups (group 1, less than 10 cigarettes per day, with 15 patients, and group 2, >10 cigarettes per day, with 10 patients) took part in the experiments. Best-corrected visual acuity (BCVA), FM100h, and A, RG, and BY contrast sensitivity functions were measured. Total and partial RG and BY error scores (TES and PTES) and colour axis index (CA) were used in the analysis. No differences between smoker and non-smoker groups were found in BCVA, CA and A and BY contrast sensitivity, but TES and PTES values and RG contrast sensitivity at 1 cpd were statistically different. Differences between smoker groups were not significant. Error scores in smokers were positively correlated with the number of cigarettes smoked per day, and in BY also with age. Tobacco caused discrimination losses in both chromatic mechanisms but affected the red-green pathway more than the blue-yellow, and therefore, a partial RG score of FM100h test seems to be a good predictor of smoker colour deficiencies.


Assuntos
Sensibilidades de Contraste , Fumantes , Cor , Percepção de Cores , Humanos , Fumar
2.
J Clin Med ; 10(19)2021 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-34640506

RESUMO

We have assessed the spectral transmittance of the different layers of the human cornea in the ultraviolet (UV), visible, and near-infrared (IR) spectral ranges. Seventy-four corneal sample donors were included in the study. Firstly, the corneal transmittance was measured using a spectrophotometer. Then, all samples were fixed for histopathological analysis, which allowed us to measure the thickness of each corneal layer. Finally, the absorption coefficients of the corneal layers were computed by a linear model reproducing total transmittance. The results show that corneal transmission was almost in unity at the visible and IR ranges but not at the UV range, in which the layer with higher transmission is Descemet's membrane, whereas the stroma showed the lowest transmittance. Regarding the absorption coefficient, the most absorptive tissue was Bowman's layer, followed by the endothelium. Variations on transmittance due to changes in the stroma, Bowman's layer, or Descemet layer were simulated, and important transmission increases were found due to stroma and Bowman changes. To conclude, we have developed a method to measure the transmittance and thickness for each corneal layer. All corneal layers absorb UV light to a greater or lesser extent. The absorption coefficient is higher for Bowman's layer, while the stroma is the layer with the lowest transmittance due to its thickness. Variations in stroma thickness or changes in the corneal tissue of Bowman's layer or the endothelium layer due to some pathologies or surgeries could affect, to a greater or lesser degree, the total transmission of the cornea. Thus, obtaining accurate absorption coefficients for different layers would help us to predict and compensate these changes.

3.
Optom Vis Sci ; 95(12): 1129-1134, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30451807

RESUMO

SIGNIFICANCE: We have analyzed the ultraviolet transmittance of some commercial intraocular lenses (IOLs). The results show differences of wavelength cutoff among them. PURPOSE: The purpose of this study was to measure and compare the ultraviolet light transmittance of different IOLs made out of acrylic hydrophobic, hydrophilic, and hydrophilic with hydrophobic surface materials from different manufacturers. METHODS: The spectral transmission curves of eight monofocal IOLs with the same dioptric power of +20.0 diopters were measured using a PerkinElmer Lambda 35 ultraviolet/visible spectrometer. Two IOLs of each type were tested three times. The ultraviolet cutoff wavelength at 10% transmission and the mean values were calculated. RESULTS: All lenses prevented transmission of ultraviolet C (200 to 280 nm) and B radiation (280 to 315 nm). However, not all IOLs provided the same filtering properties in ultraviolet A (315 to 380 nm). Within the ultraviolet A range, the ultraviolet radiation cutoff wavelength of 10% ranges from approximately 360 to 400 nm. HOYA iSert 250 provided a cutoff wavelength of 398.4 nm; AcrySof SA60AT, 396.2 nm; AcrySof SA60WF, 395.7 nm; CT Asphina 404, 378.34 nm; Tecnis ZCB00, 377.70 nm; CT Lucia 607P, 379 nm; C-Flex 570C, 377 nm; and enVista MX60, 360 nm. CONCLUSIONS: Intraocular lenses of different materials and manufacturers have different ultraviolet transmission characteristics. AcrySof (SA60AT and SA60WF) and HOYA iSert 250 provided the highest ultraviolet radiation transmission; the cutoff wavelength of 10% is close to 400 nm. In contrast, enVista IOL showed the lowest ultraviolet radiation cutoff.


Assuntos
Lentes Intraoculares , Óptica e Fotônica , Proteção Radiológica/instrumentação , Raios Ultravioleta , Resinas Acrílicas , Materiais Biocompatíveis , Filtração , Humanos , Polimetil Metacrilato , Elastômeros de Silicone , Espectrofotometria Ultravioleta
4.
Optom Vis Sci ; 95(11): 1054-1063, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30339643

RESUMO

SIGNIFICANCE: Apple devices could be suitable for vision tests, provided that the test has been correctly adapted to the device, after considering the spatial and colorimetric characterization of the screen. PURPOSE: The majority of vision applications has not been developed by vision or colorimetry experts and suffers from conceptual and design errors that may lead average users to an erroneous assessment of their visual capabilities. The reliability of vision tests depends on the accurate generation of the necessary visual stimuli in a particular device. Our aim was to ascertain whether a given color test, designed for a colorimetrically characterized device, might be used in another similar device. METHODS: We evaluated color reproduction errors in three iPad tablets of different models with Retina screens, using their individual color characterization models and the model derived for another device. RESULTS: Our results showed, even with this small sample, the high degree of error caused when disregarding the fact that the colorimetric design valid for a given device may not be correct when displayed in another. CONCLUSIONS: The distortion of the chromatic content may lead to subjects with vision defects to pass as normal or vice versa, compromising diagnosis reliability.


Assuntos
Testes de Percepção de Cores/métodos , Percepção de Cores/fisiologia , Defeitos da Visão Cromática/diagnóstico , Computadores de Mão , Diagnóstico por Computador/instrumentação , Defeitos da Visão Cromática/fisiopatologia , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes
5.
Exp Eye Res ; 140: 190-192, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26386149

RESUMO

In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation.


Assuntos
Técnicas de Diagnóstico Oftalmológico/instrumentação , Lentes Intraoculares , Óptica e Fotônica , Reprodutibilidade dos Testes
6.
J Refract Surg ; 31(4): 230-5, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25884577

RESUMO

PURPOSE: To evaluate the effect of pupil size on image quality of a sectorial multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), and the Acri.LISA IOL (Carl Zeiss Meditec, Jena, Germany). METHODS: The authors measured the MTFs of the Lentis Mplus LS-312 IOL and the Acri.LISA 366D IOL with three different sizes of pupil diameters: 3, 4, and 5 mm. The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Science Ltd., Oxford, UK) by using fast Fourier-transform techniques. RESULTS: In distance focus, the image quality provided by the Lentis Mplus IOL was better than that of the Acri. LISA IOL with all pupil diameters. In near focus, the MTF of the Acri.LISA IOL was better with a 3-mm pupil, but poor with larger pupils. The aberration effect was equal in both IOLs in distance focus, but in near focus and with a 3-mm pupil, the Acri.LISA IOL was less affected by the aberration than the Lentis Mplus IOL. CONCLUSION: The Lentis Mplus IOL provides better distance image quality than the Acri.LISA IOL, whereas the near image quality of the Acri.LISA IOL is better with small-pupil diameter. The sectorial design makes this IOL more suitable for patients with a pupil diameter greater than 3 mm.


Assuntos
Lentes Intraoculares , Óptica e Fotônica , Pupila/fisiologia , Análise de Fourier , Humanos , Modelos Teóricos
7.
Eur J Ophthalmol ; 21(5): 597-603, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21240861

RESUMO

PURPOSE: An increase in lens thickness is often described as a linear function of age. However, contradictory opinions exist about whether the lens thickness continues to increase after 50 years of age. Differences in slope exist between this increase in younger and older people, but these findings are inconsistent with the linear behavior of an increase in the lens thickness throughout life. We investigated among different functions, including slope variation, which would be the best to show the relation between lens thickness and age. An available model portraying lens growth could be advantageous in many practical applications. The possibility of differences between sexes in lens thickness growth is also analyzed. METHODS: We evaluated 102 eyes of patients aged between 15 and 84 years: 41 men, 61 women. The biometric measurements were performed with the aid of the OcuScan® (Alcon, USA). RESULTS: Both logarithmic and potential functions provide a good fit for the data (R2 = 0.905 and 0.906, respectively). The results do not show significant differences between men and women in any age range, nor when the data of the whole sample are considered (p = 0.29). CONCLUSIONS: The best fits for the data are both logarithmic and double logarithmic functions. According to this model, lens growth continues throughout life, but after 50 years, age-related thickness variations are lower than statistical variability. No differences were found between the sexes.


Assuntos
Envelhecimento/fisiologia , Cristalino/anatomia & histologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biometria , Feminino , Humanos , Cristalino/crescimento & desenvolvimento , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...